Refinery Analysers
  • Comprehensive Solutions for the Reinery Industry
  • Worldwide support for products in the field
  • Extensive references & experience in Emissions Monitoring
 
Home > Industries > Refineries

Refinery Emissions Monitoring & Analysis

Procal supplies both refinery process and refinery emissions monitoring analysers to meet a wide range of applications. 

Crude Oil Heaters / Furnaces / Incinerators 
Procal 2000 measures products of combustion and can accommodate changes caused by variations in the make up of off-gas fuel. The heated probe option is especially suited to this application as it efficiently deals with variations in process temperature. It also keeps the probe hot, ensuring immediate availability when the plant is restarted after an outage. 

Gas Ranges to Suit Process
SO2 0 – 2,000 ppm
NO 0 – 500 ppm
NO2 0 – 500 ppm
H2O 0 – 15%

 
Power Plant– Electricity and Steam
Procal 2000 is the ideal field-proven device to monitor emissions from refinery power plants. The instrument is compliant with international standards therefore meeting the stringent requirements of Environment Agencies.
 
Gas Ranges to Suit Process
CO 0 – 200 ppm
NOx 0 – 500 ppm
NO2 0 – 500 ppm
CO2 0 – 15%

Klaus Unit 
Capable of reliably measuring the high concentrations of SO2 found in a Klaus Unit, Procal 2000 can be offered with special corrosion-resistant materials such as Hastelloy ‘C’. Procal 2000 is the only in-situ IR analyser on the market that is available with optional ATEX / IEC approval for use in ZONE 1 Hazardous Areas such as those found in many refinery applications. 
 
Gas Ranges to Suit Process
SO2 0 – 2%
H2S 0 – 2%
Catalyst Cracker Vent 
This is an application for which the Procal 2000 analyser is well suited. In cases where dust levels in the sample are high, the sintered filter assembly can function well even at levels of a few g/m3
 
In addition to ATEX / IEC approved analysers, Procal offer a range of accessories suitable for installation in hazardous areas. For example, steam-heated probes and bypasses can be used to ensure that the sample temperature is maintained above the acid dew point.
 
Gas Ranges to Suit Process
SO2 (normal) 0 – 700 ppm
SO2 (plant upset) 0 – 14,000 ppm
NO 0 – 300 ppm
NO2 0 – 250 ppm
 
This is an application for which the Procal 2000 analyser is well suited. In cases where dust levels in the sample are high, the sintered filter assembly can function well even at levels of a few g/m3. 
 
In addition to ATEX / IEC approved analysers, Procal offer a range of accessories suitable for installation in hazardous areas. For example, steam-heated probes and bypasses can be used to ensure that the sample temperature is maintained above the acid dew point.
 
Quick Contact
security code
Security code:
Approvals held within the Kittiwake Group
IEC ATEX GL-Group Investors in People Logo IRQA Lloyds Register ABS CERTI SIRA MCA Mared